Cable

Cable top picks

RR Kabel

Process Field Bus

  • Adapted to DIN 19245 & EN 50170
  • 250V (not for power installation)
  • 5000 G x cm
RR Kabel

Elastomeric Battery Cable

  • Adapted to BS 6862
  • Max. 200V
  • 1000 Volts
RR Kabel

PVC Battery Cable

  • Max. 200V
  • 1000 Volts
  • -30°C to +70°C
RR Kabel

LIYY (TP)

  • PVC self-extinguishing and flame retardant according to EN 60332-1-2.
  • LiYY (TP) is applicable in the short runs and tight spaces, where the main requirements are smaller outer diameter and bending radii. The cable ideally meets these requirements.
RR Kabel

LIYY

  • These are special PVC data cables used for flexible use with free movement without tensile stress of forced movements in dry, moist and wet rooms but not suitable for open air, wherever the construction requirements call for a minimum outer diameter.
RR Kabel

LIYCY (TP)

  • The high level of screening reduces substantially the effects of electrical disturbances. These cables are used for data & signal transmission. These cables are integral part of instrumentation in industries for precise signal and data transmission.
  • PVC self-extinguishing and flame retardant according to EN 60332-1-2. The twisted pair construction further reduces crosstalk and electromagnetic interferences, enhancing the signal transmission characteristics
RR Kabel

LIYCY

  • These cables are used for data and signal transmission application in the electronics of computer systems, electronic control equipment and measuring devices in the tool making and machine industries. The optimum screening substantially reduces the effect of electromagnetic interferences.
  • PVC self-extinguishing and flame retardant according to EN 60332-1-2.
RR Kabel

Ratnaflex Multicore Cable (IS 694)

  • IS 694 marked, FIA/TAC
  • Electrolytic grade annealed copper Class 5 as per IS 8130
  • Black, grey & white
RR Kabel

Control Cable (IS 694)

  • IS 694 marked, FIA/TAC
  • Electrolytic grade annealed copper Class-5 as per IS 8130, having uniform resistance properties
  • All black colour cores with continous white numbering, gn-yl core on outer most layer for earth if applicable
RR Kabel

JZ-BLACK 0.6/1 KV

  • Uo / U 0.6 / 1 kV
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kabel

UL 2586

  • UL-758 UL 2586
  • 1000 Vac
  • -30ºC to + 150 ºC
RR Kabel

UL 2587

  • Std. 758; Control cable of special – PVC to UL AWM; Style 2587 cores according to UL 1015
  • 600V
  • 3000V
RR Kabel

JB-750

  • Uo/U 450/750V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C
RR Kabel

H03/H05V2V2H2-F & H03/H05V2V2-F

  • 300 / 500V (H05V2V2H2-F / H05V2V2-F); 300 / 300V (H03V2V2H2-F / H03V2V2-F)
  • Min. 20 GΩ x cm
  • Flexing -5°C to +90°C / Fixed Installation -30°C to +90°C / Fixed Installation 5 x cable ø
RR Kabel

JB-BLACK 0.6/1 KV

  • Uo / U 0.6 / 1 kV
  • Min. 20 GΩ x cm
  • Occasional flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kabel

H05Z1Z1-F (318B)

  • U / U 300/500 V
  • Flexing -5°C to +70°C. Fixed Installation : -30°C to +70°C
  • Flexing 7.5 x cable ø; Fixed installation 4 x cable ø
RR Kabel

PVC/PVC 3 Core Submersible Flat Cable

  • IS 694 marked, FIA/TAC
  • Electrolytic grade annealed copper
  • Red, yellow (centre core), blue
RR Kabel

XLPE/PVC 3 Core Submersible Flat Cable

  • Electrolytic grade annealed plain copper to EN 60228, uniformly bunched to form a circular shape
  • Red, yellow (centre core), blue
  • Black
RR Kabel

PVC/PVC Twin Core Flat Cable (IS 694)

  • IS 694 marked, FIA / TAC
  • Electrolytic grade annealed copper
  • Red, black
RR Kabel

LS0H-FR

  • IS 17048 marked, FIA/TAC
  • Z
  • Up to and including 1100V
RR Kabel

Firex Ls0h-Ebxl

  • IS 17048 marked, FIA/TAC
  • XZ
  • Up to and including 1100V
RR Kabel

Halogen-Free H07Z-R-6491B

  • Uo / U – 450 / 750V
  • 1.5 mm² to 630 mm² stranded class 2 – H07Z-R
  • -15°C to 90°C
RR Kabel

H05Z1Z1-F (318B)

  • U / U 300/500 V
  • Flexing -5°C to +70°C. Fixed Installation : -30°C to +70°C
  • Flexing 7.5 x cable ø; Fixed installation 4 x cable ø
RR Kabel

JB-H

  • UO / U 450 / 750V
  • Flexing -15°C to +70°C. Fixed installation -30°C to +70°C
  • Flexing approx. 15 x cable ø. Fixed installation approx. 4 x cable ø
RR Kabel

JZ-H

  • UO / U 300 / 500V
  • Flexing -15°C to +70°C. Fixed installation -30°C to +70°C
  • Flexing approx. 10 x cable ø. Fixed installation approx. 4 x cable ø
RR Kabel

JZ-HCH

  • Uo / U 300 / 500V
  • Flexing -15°C to +70°C. Fixed installation -30°C to +70°C
  • Flexing approx. 15 x cable ø. Fixed installation approx. 6 x cable ø
RR Kabel

POWER CABLE - BS 5467

  • 600/1000V
  • 15 x Cable diameter
  • 90°C
RR Kabel

EAXVB

  • U0 / U 0.6/1.0 kV
  • -5°C to 90°C
  • 12 x D
RR Kabel

EXVB

  • Uo / U 0.6/1.0 kV
  • -5°C to 90°C
  • 12 x D
RR Kabel

JZ-500

  • Uo / U 300 / 500V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kabel

Control Cable (IS 694)

  • IS 694 marked, FIA/TAC
  • Electrolytic grade annealed copper Class-5 as per IS 8130, having uniform resistance properties
  • All black colour cores with continous white numbering, gn-yl core on outer most layer for earth if applicable
RR Kabel

JZ-CY

  • Uo / U 300 / 500V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kabel

JZ-YCY

  • Uo /U 300 / 500V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kabel

JZ-YSY

  • Uo / U 300 / 500V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kabel

JB-YCY

  • Uo / U 300 / 500V up to 1.5 mm². Uo / U 450 / 750V for 2.5 mm² and above
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kabel

JB-YSY

  • Uo / U 300 / 500V up to 1.5 mm². Uo/U 450/750V for 2.5 mm² and above
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C; Fixed installation -30°C to +70°C
RR Kabel

JZ-YCY BK 0.6/1.0 KV

  • Uo / U 0.6 / 1 kV
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kabel

JB-BLACK 0.6/1 KV

  • Uo / U 0.6 / 1 kV
  • Min. 20 GΩ x cm
  • Occasional flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kabel

OZ-EB

  • UO / U 300 / 500V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kabel

OZ-EB CY

  • UO / U 300 / 500V.
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kabel

JB-H

  • UO / U 450 / 750V
  • Flexing -15°C to +70°C. Fixed installation -30°C to +70°C
  • Flexing approx. 15 x cable ø. Fixed installation approx. 4 x cable ø
RR Kabel

JZ-H

  • UO / U 300 / 500V
  • Flexing -15°C to +70°C. Fixed installation -30°C to +70°C
  • Flexing approx. 10 x cable ø. Fixed installation approx. 4 x cable ø
RR Kabel

JZ-HCH

  • Uo / U 300 / 500V
  • Flexing -15°C to +70°C. Fixed installation -30°C to +70°C
  • Flexing approx. 15 x cable ø. Fixed installation approx. 6 x cable ø
RR Kabel

H03/H05VVH2-F & H03/H05VV-F

  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C.
  • -30°C to +70°C
RR Kabel

JB-750

  • Uo/U 450/750V
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C
RR Kabel

H05Z1Z1-F (318B)

  • Flexing -5°C to +70°C.
  • -30°C to +70°C
  • Flexing 7.5 x cable ø; Fixed installation 4 x cable ø
RR Kabel

JZ-YCY BK 0.6/1.0 KV

  • UO / U 0.6 / 1kV
  • Min. 20 GΩ x cm
  • Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
RR Kabel

UL 2464

  • UL- Std. 758. Special PVC command cable, approved to UL-Style 2464, cores according to AWG 24-16 to UL-Style 1007/1569
  • 300V
  • 1500V
RR Kabel

UL 2576, 2598

  • UL – Std. 758; UL – Style 2576, 2598
  • 300V
  • -20°C to + 80°C
RR Kabel

LI2Y(St)CY (TP)

  • Based on VDE 0812
  • Max. 250 V
  • Core/core 2000 V. Core/screen 1000 V
RR Kabel

Firex Ls0h-Ebxl

  • IS 17048 marked, FIA/TAC
  • XZ
  • Up to and including 1100V
RR Kabel

Halogen-Free H07Z-R-6491B

  • Uo / U – 450 / 750V
  • 1.5 mm² to 630 mm² stranded class 2 – H07Z-R
  • -15°C to 90°C